largest bounded bus peak: 7.038 A.
largest bounded bus RMS: 4.232 A.
pooled whole-body torque-producing RMS across both prescribed sequences.
gripper sequence envelopes use an explicit virtual-work map; active object gripping remains excluded.
Eight bus envelopes
| Bus | Peak | P95 | RMS | Internal-cap sum |
|---|---|---|---|---|
| RS-LARM | 0.338 A | 0.320 A | 0.189 A | 5.996 A |
| RS-LLEG | 7.033 A | 5.940 A | 4.229 A | 13.993 A |
| RS-RARM | 0.332 A | 0.314 A | 0.183 A | 5.996 A |
| RS-RLEG | 7.038 A | 5.943 A | 4.232 A | 13.993 A |
| RS-WAIST | 0.009 A | 0.008 A | 0.003 A | 2.499 A |
| TTL-HEAD | 0.047 A | 0.044 A | 0.044 A | 1.400 A |
| TTL-LDIST | 0.002 A | 0.002 A | 0.001 A | 1.400 A |
| TTL-RDIST | 0.003 A | 0.003 A | 0.001 A | 1.400 A |
Deliberate boundary
These values include commanded torque or generalized gripper-hold force only. Actuator logic/idle current, driver loss, bus transients, inrush, active grip force, regeneration, stalled/fault states, free-balance corrections, environmental variation and as-built efficiency are absent. Therefore this package cannot release conductors or protection. It supplies a reproducible bounded duty case for later thermal and fault tests.